EATON POWERWARE 93E
User Interface
Large LCD graphically displays UPS status and offers easy access to measurements, controls and settings.
Energy-efficient design
With a transformer-free design and sophisticated sensing and control circuitry the 93E is capable of achieving up to a 99% efficiency raing, making it one of the most energy-efficient UPSs in its class - and it still provides maximum load protection. Unlike most hign efficiency UPSs, the 93E :
• Provides surge suppression for the load
• Detects the location of faults (utility or load) and takes the appropriate action
• Switches to double-conversion operation in less than 4ms
High system efficiency reduces utility cost, extends battery run times and ensures cooler operating conditions.
The Eaton 93E : simply effective
The Eaton 93E UPS delivers simply effective power protection for ever-expanding loads in today's space-constrained data centers. Facilitating a lower total cost of ownership (TCO) through a combination of energy-efficiency, high reliability and a compact footprint the 93E is an ideal solution for small - to mediun - sized centres and other applications desiring highly reliable power protection.
Real compatibility
Active power factor correction (PFC) provides 0.99 input power factor and < 5% ITHD, thus eliminating interference with other critical equipment in the same network and enhancing compatibility with generators. The 93E is optimised for protecting modern 0.9 p.f rated IT equipment without the need to oversize.
True reliability
Patented Powerware Hot Sync®technology makes it possible to parallel up to four UPSs to increase availability or add capacity
The technology enables load sharing without any communication line, thus eliminating single point of failure.
Compact & serviceable design
Small footprint occupies minimal floor space:
• Up to 60% smaller than similar competitive solutions
• The 93E is easily and quickly serviced to provide the highest level of availability with Mean Time to Repair (MTTR) < 30 minutes. With its Easy Capacity Test feature the 93E can test its entire power train under full load stress without the requirement of an extermal load.
TECHNICAL SPECIFICATIONS
| Power | |
|---|---|
| Ratings | 15kVA/13.5kW 20kVA/18kW
30kVA/27kW 40kVA/36kW
60kVA/54kW 80kVA/72kW 100kVA/90kW 120kVA/108kW 160kVA/144kW 200kVA/180kW 300kVA/270kW 400kVA/360kW 500kVA/450kW |
| Topology | Double-conversion online UPS |
| Operating Frequency | 50/60 Hz (40 ~ 72 Hz) |
| Input Power Factor | 0.99 typical |
| Input Current Distortion | ≤5% THD |
| Electrical input | |
| Nominal input Voltage | 400/230, 3/4 w ire (380/415V selectable) |
| Input voltage rangen | -15%, +20% from nominal (400V) at 100% load without depleting battery |
| Electrical output | |
| Nominal Output Voltage | 400/230, 3/4 w ire (380/415V selectable) |
| Output voltage regulation | ±1% Static; <5% dynamic at 100% resistive load change, <20 ms response time |
| Battery | |
| Battery | 192 to 240 Cells (Continual selectable for 15-80kVA) 216/222/228/234/240 Cells (Selectable for 100-500kVA) |
| Charging Method | ABM Cyclic Charging |
| General | |
| Efficiency | >98% High-efficiency mode (15-80kVA) >98.5% High-efficiency mode (100-300kVA) >99% High-efficiency mode (400-500kVA) >94% Double conversion mode (15-300kVA) >96% Double conversion mode (400-500kVA) |
| Overload | 150% for 1 minute, 125% for 10 minutes >150% for 150ms |
| UPS Bypass | Automatic on overload or UPS failure |
| Parallel technology | Powerware Hot Sync® Technology |
| Dimensions W x D x H, (mm) |
500 x 710 x 960 / 15-20kVA (with internal battery) 500 x 710 x 1230 / 30kVA (with internal battery) 500 x 710 x 1500 / 40kVA (with internal battery) 600 x 800 x 1876 / 60-200kVA 1600 x 820 x 1880 / 300/400/500kVA |
| Cabinet rating | IP20 with standard washable dust filters |
| Weights without internal battery |
72kg 15/20kVA 91kg 30kVA 120kg 40kVA 202kg 60kVA 245kg 80kVA 283kg 100kVA 311kg 120kVA 457kg 160/200kVA 860kg 300kVA 970kg 400kVA 1020kg 500kVA |
| Weights with internal battery |
272kg 15/20kVA 376kg 30kVA 490kg 40kVA |
| Communications | |
| Display | Graphical LCD with blue backlight |
| LEDs | (4) LEDs for notice and alarm |
| Audible Alarms | Yes |
| Communication Ports | (1) RS-232, (1) USB, (1) EPO |
| Communication Slot | (2) Mini-slot communication bays |
| Environmental | |
| Operating Temperature | 0ºC to +40ºC Batteries recommended max. +25ºC |
| Storage Temperature | -25ºC to +55ºC without batteries +15ºC to +25ºC with batteries |
| Relative Humidity | 5–95%, non-condensing |
| Audible Noise | 15-20kVA≤55 dBA at 1m typical 30-40kVA≤62 dBA at 1m typical 60-120kVA≤65 dBA at 1m typical 160-200kVA≤70 dBA at 1m typical 300-400kVA≤73 dBA at 1m typical 500kVA≤75dBA at 1m typical |
| Altitude | <1000m at +40°C |
| Certifications | |
| EMI Standards | EN55022/EN55024 |
| EMC Compliance | IEC 62040-2 |
| Quality | ISO 9001: 2000 and ISO 14001:1996 |
| Communication accessories | |
| Network-MS | Web/SNMP Card |
| Modbus-MS | Web/SNMP and Modbus Card |
| Relay-MS | Relay (Dry Contact) Card -DB9 Connection |
| Industrial Relay | Relay (Dry Contact) Card -Terminal Connection |
| 116750224-001 | Environmental Monitor Probe (EMP) kit (need to plug into Web/SNMP Card or Web/SNMP and Modbus Card to work |
| System accessories | |
| Battery cabinets & battery circuit breakers (60-200kVA) | |
| Maintenance Bypass Switches (MBS) (100-200kVA, standard on 15-80kVA) | |
| Top cable entry (60-200kVA, standard on 300-500kVA) | |
| System parallel modules (60-200kVA) | |
| Dual input kit (15-80kVA) | |
| IP21 hood (15-200kVA) | |
| Rear chimney (60-200kVA) | |